Welltech SPCI2S Intel NetStructure SS7 Boards Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Komunikacja Welltech SPCI2S Intel NetStructure SS7 Boards. Welltech SPCI2S Intel NetStructure SS7 Boards User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - SPCI4 and CPM8

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 1 Intel® NetStructure™ SS7 Boards Programmer’s Manual for SPCI2S, SPCI4 and CPM8 Do

Strona 2

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 10 To automatically start the driver at system startup, select the ’Automatic’ optio

Strona 3 - Contents

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 100 Bit 1 is set to 1 to cause a signalling link test (in accordance with ITU-T Q.70

Strona 4

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 101 A2.4 MTP Route Syntax: MTP_ROUTE <dpc> <norm_ls> <user_part_mask&

Strona 5

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 102 Bit 1 is used to determine whether or not to load share messages across the two

Strona 6

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 103 A2.5 MTP User Part Syntax: MTP_USER_PART <si> <module_id> Example: M

Strona 7

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 104 A3 ISUP Parameters A3.1 Global ISUP Configuration Syntax: ISUP_CONFIG <res1&g

Strona 8

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 105 <gid > The group id of the circuit group in the range 0 to one less than t

Strona 9

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 106 A4 TUP Parameters A4.1 Global TUP Configuration Syntax: TUP_CONFIG <res1>

Strona 10

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 107 <gid > The group id of the circuit group in the range 0 to one less than

Strona 11

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 11 2.2 Software Installation for Linux* The Development Package for Linux is distrib

Strona 12

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 12 2.2.1 Creating Linux device nodes The Linux device driver is a run-time loadable

Strona 13

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 13 The -f option is used to force loading of the driver even if it was built using a

Strona 14

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 14 2.3 Software Installation for Solaris* The Development Package for Solaris is dis

Strona 15

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 15 On successful completion of the procedure the following message is displayed and

Strona 16 - Programmer’s Manual

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 16 3. CONFIGURATION AND OPERATION 3.1 Overview Prior to attempting software configur

Strona 17

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 17 The following abbreviations are used in the table: MTP2 - Message Transfer Par

Strona 18 - 0x12 *(Hexadecimal)

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 18 3.2 System Configuration System configuration is handled by the program gctload w

Strona 19

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 19 b) REDIRECT commands to cause messages generated for modules not running locally

Strona 20

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 2 Revision History ISSUE DATE CHANGES A 12-Apr-00 Initial release for evaluatio

Strona 21

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 20 3.2.2 Generating system.txt This section describes the procedure for generating a

Strona 22

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 21 It is next necessary to include FORK_PROCESS commands for all modules running on

Strona 23

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 22 3.3 Protocol Configuration The Development Package contains a protocol configurat

Strona 24

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 23 calling the library function relm(). The library functions are all described in t

Strona 25

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 24 3.4 Using the CT bus 3.4.1 Introduction The SPCI2S, SPCI4 and CPM8 cards support

Strona 26

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 25 When a new call arrives the application will, in general, need to initiate two li

Strona 27

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 26 3.4.5 Example code - Building and sending SC_LISTEN /* * Example function for bu

Strona 28

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 27 4. PROGRAM EXECUTION This section describes how to start the software running. It

Strona 29

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 28 4.1 Program execution under Windows Ensure the device driver has been installed a

Strona 30

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 29 4.2 Program execution under Linux Ensure the device driver has been installed and

Strona 31

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 3 Contents 1. INTRODUCTION ...

Strona 32

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 30 4.3 Program execution under Solaris Ensure the device driver has been installed a

Strona 33

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 31 4.4 Developing a user application The Development Package, along with the User Pa

Strona 34

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 32 5. APPLICATION MESSAGE SPECIFICATIONS 5.1 Overview This section describes the ind

Strona 35

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 33 5.1.3 MTP Interface Messages MTP Interface Messages allow signalling links to be

Strona 36

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 34 0x3e1f Confirmation of MVD_MSG_SC_CONNECT 0x3e20 Confirmation of MVD_MSG_CN

Strona 37

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 35 5.2 General Configuration Messages 5.2.1 SSD Reset Request Synopsis: Message sen

Strona 38

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 36 Parameter Description: mgmt_id The module_id of the management module to which

Strona 39 - Synopsis:

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 37 5.2.2 Board Reset Request Synopsis: Message sent to SSD to cause a single board

Strona 40

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 38 Parameter Description: board_type The type of board to be reset. This should be

Strona 41

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 39 5.2.3 Board Configuration Request Synopsis: Message sent to a board immediately

Strona 42

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 4 5.3.5 LIU State Request...

Strona 43

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 40 Message Format: MESSAGE HEADER FIELD NAME MEANING type MGT_MSG_CONFIG0 (0x7F10)

Strona 44

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 41 Description: This message must be the first message sent to the board once the S

Strona 45

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 42 Bit 6 and 7 together select the initial CT bus clocking mode as shown in the fol

Strona 46

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 43 l3_flags - level 3 flags Bit 0 is set to 1 to disable the level 3 discrimination

Strona 47

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 44 linkn_flags - Per link flags Bit 0 is set to 1 to force the use of the emergency

Strona 48

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 45 linkn_slc - Signalling link code. The signalling link code for the link which mu

Strona 49

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 46 5.2.4 MTP Route Configuration Request Synopsis: Message sent to MTP3 to add a ro

Strona 50

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 47 The confirmation message (if requested) will indicate success by a status of 0.

Strona 51

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 48 flags This field is a 16 bit field containing run-time configuration options for

Strona 52

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 49 5.3 Hardware Control Messages 5.3.1 LIU Configuration Request Synopsis: Message

Strona 53

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 5 1. INTRODUCTION The range of Intel NetStructure SS7 Boards includes specialised

Strona 54

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 50 Description: This message is sent to the board to configure the operating mode a

Strona 55

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 51 frame_format The frame format taken from the following table: frame_format Descr

Strona 56

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 52 ais_gen The (initial) mode used to generate the Alarm Indication Signal (Blue Al

Strona 57

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 53 5.3.2 LIU Control Request Synopsis: Message sent by the application to dynamical

Strona 58

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 54 Parameter Description: ais_gen The mode used to generate the Alarm Indication Si

Strona 59

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 55 5.3.3 LIU Read Configuration Request Synopsis: Message sent by the application t

Strona 60

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 56 5.3.4 LIU Read Control Request Synopsis: Message sent by the application to read

Strona 61

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 57 5.3.5 LIU State Request Synopsis: Message sent by the application to read the cu

Strona 62

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 58 5.3.6 LIU CT bus Initialisation Request Synopsis: This message is sent to the bo

Strona 63

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 59 sc_channel The channel number of the first channel to be used on the CT bus. Thi

Strona 64

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 6 1.1 Related Documentation U02HSP - CPM8 User Manual U04HSP - SPCI2S, SPCI4 User Ma

Strona 65

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 60 5.3.7 CT bus Listen Request Synopsis: Message sent to the board to establish a c

Strona 66

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 61 Parameter Description: liu_id The identifier of the E1/T1 Line Interface Unit in

Strona 67

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 62 5.3.8 Fixed Data Output Request Synopsis: Message sent to the board in order to

Strona 68 - 8 Mb/s 0 .. 128

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 63 pattern The value of the fixed data to be generated. The value should be in the

Strona 69

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 64 5.3.9 Reset Switch Request Synopsis: Resets the digital switch to its default st

Strona 70

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 65 5.3.10 CT bus Connect Request Synopsis: Message sent to the board to control the

Strona 71

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 66 Parameter Description: The following table depicts which parameters are required

Strona 72

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 67 mode The value of the mode parameter determines which of the following operatio

Strona 73

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 68 source_slot The source slot references the CT bus timeslot from which to connec

Strona 74

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 69 5.3.11 Configure Clock Request Synopsis: Message sent to a SPCI2S, SPCI4 or CPM8

Strona 75

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 7 2. INSTALLATION 2.1 Introduction This programmer’s manual covers the installation

Strona 76

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 70 Parameter Description: bus_speed This parameter is used to set the CT bus speed,

Strona 77

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 71 pll_src This parameter determines the source of the PLL reference clock, the per

Strona 78

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 72 ref1_mode This parameter determines whether the CT bus NETREF_1 clock is driven

Strona 79

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 73 5.3.12 Configure Clock Priority Request Synopsis: Message sent to a SPCI2S, SPCI

Strona 80

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 74 Parameter Description: liun_pri The relative priority for each LIU using the val

Strona 81

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 75 5.4 MTP Interface Messages 5.4.1 MTP Link Activation Request Synopsis: Primitive

Strona 82

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 76 5.4.2 MTP Link Deactivation Request Synopsis: Primitive request sent to MTP3 3 m

Strona 83

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 77 5.4.3 MTP Transfer Request Synopsis: Primitive request sent to MTP3 to convey a

Strona 84

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 78 5.4.4 MTP Transfer Indication Synopsis: Primitive indication issued by MTP3 to c

Strona 85

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 79 5.4.5 MTP Pause Indication Synopsis: Primitive request issued by MTP3 to indicat

Strona 86

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 8 2.2 Software Installation for Windows* The Development Package for Windows is dist

Strona 87

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 80 5.4.6 MTP Resume Indication Synopsis: Primitive request issued by MTP3 to indica

Strona 88

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 81 5.4.7 MTP Status Indication Synopsis: This primitive is used by level 3 to indic

Strona 89

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 82 5.5 Event Indication Messages 5.5.1 Board Status Indication Synopsis: Message se

Strona 90

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 83 5.5.2 s7_mgt Completion Status Indication Synopsis: Message issued by s7_mgt on

Strona 91

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 84 5.5.3 Clock Event Indication Synopsis: Message issued by the board to indicate o

Strona 92

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 85 5.5.4 LIU Status Indication Synopsis: Message issued by the board to notify of c

Strona 93 - A1.2 LIU_CONFIG Command

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 86 5.5.5 Error Indication Synopsis: Message issued to management to advise of errors

Strona 94

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 87 The ERROR_CODE is coded as shown in the following table: Value Mnemonic id Descri

Strona 95 - A1.3 LIU_SC_DRIVE Command

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 88 5.5.6 MTP2 Level 2 State Indication Synopsis: Indication issued by the board eve

Strona 96 - A1.4 SCBUS_LISTEN Command

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 89 5.5.7 MTP2 Q.791 Event Indication Synopsis: Message issued by MTP2 to advise man

Strona 97 - A2 MTP Parameters

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 9 The installation process automatically installs the device driver so the setup pro

Strona 98 - A2.2 MTP Link Set

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 90 5.5.8 MTP3 Q.791 Event Indication Synopsis: Message issued by MTP3 to notify man

Strona 99 - A2.3 MTP Signalling Link

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 91 APPENDIX A : PROTOCOL CONFIGURATION COMMANDS This appendix describes the commands

Strona 100

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 92 Bit 13 causes the board to drive the CT_NETREF1 clocks on the CT bus when set to

Strona 101 - A2.4 MTP Route

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 93 A1.2 LIU_CONFIG Command Syntax:LIU_CONFIG <board_id> <liu_id> <liu

Strona 102

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 94 <frame_format> The frame format taken from the following table: frame_forma

Strona 103 - A2.5 MTP User Part

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 95 A1.3 LIU_SC_DRIVE Command Syntax: LIU_SC_DRIVE <board_id> <liu_id> &l

Strona 104 - A3 ISUP Parameters

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 96 A1.4 SCBUS_LISTEN Command Syntax: SCBUS_LISTEN <board_id> <liu_id> &l

Strona 105

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 97 A2 MTP Parameters A2.1 MTP Global Configuration Syntax: MTP_CONFIG <reserved1&

Strona 106 - A4 TUP Parameters

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 98 A2.2 MTP Link Set Syntax: MTP_LINKSET <linkset_id> <adjacent_spc> <

Strona 107

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 99 A2.3 MTP Signalling Link Syntax: MTP_LINK <link_id> <linkset_id> <

Komentarze do niniejszej Instrukcji