Welltech SPCI2S Intel NetStructure SS7 Boards Instrukcja Użytkownika Strona 45

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 107
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 44
SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 45
link
n
_slc - Signalling link code.
The signalling link code for the link which must be in the range 0 to 15. The
signalling link code must be agreed with the administration at the other end of
the link and must be unique within a link set. Usually the first link in a link set is
assigned the value 0, the next one and so on.
link
n
_adj_pc - Adjacent point code.
The point code of the signalling point at the remote end of the link. Should be in
the range 0 to 16383 for 14 bit point code operation or 0 to 16777215 for 24 bit
point code operation. (
Note that all links in a link set must have the same
adjacent point code
).
link
n
_stream - Signalling stream.
When linkn_timeslot is set to a non-zero value, the linkn_stream is the logical
identity of the E1 / T1 line interface (liu_id - in the range 0 to one less than the
number of LIUs fitted) containing the signalling link.
link
n
_timeslot - Signalling timeslot.
The timeslot used for signalling in the range 1 .. 31. For an E1 interface the
valid range is 1 .. 31. For a T1 interface the valid range is 1 .. 24. Alternatively
timeslot can be set to zero and the switch path set up manually using the switch
control messages.