Welltech WellGate M1 Instrukcja Użytkownika Strona 51

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 58
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 50
WellGate M1 Web user guide
Welltech Technology Co., Ltd.
51 / 58 2014/12/1
Item
Description
Hi-Tone Freq
Default: 440; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Lo-Tone Freq
Default: 350; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Hi-Tone Gain
Default: 4522; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
Lo-Tone Gain
Default: 2261; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
On Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
On Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
On Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Busy
Busy Tone configuration.
Candence On
Default is enable
Hi-Tone Freq
Default: 440; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Lo-Tone Freq
Default: 350; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Hi-Tone Gain
Default: 4522; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
Lo-Tone Gain
Default: 2261; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
On Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
On Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
On Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Off Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~ 999, Maximum length: 3 bytes.
Congestion
Congestion tone configuration
Candence On
Default is enable.
Hi-Tone Freq
Default: 440; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Lo-Tone Freq
Default: 350; Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Hi-Tone Gain
Default: 4522; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
Przeglądanie stron 50